Metal Building for Simpson, North Carolina Build and Buy Online!
Mini Storage BuildingsIf you have thought of being a small business owner you might consider the self-storage market. Self-storage and mini storage buildings are a fairly inexpensive way to start a business that is designed to bring in dependable monthly revenue. Many storage facilities currently have waiting lists due to the ever-growing need for space. Mini storage buildings can be designed to include any number of individual units, depending on the site constraints. Steel frame mini storage buildings can be designed with a variety of options. Metal Church BuildingsChurches often grow quickly and are unable to successfully provide service to the people in the community. Metal church buildings are a great way to address emerging parishioners and a need for space. You can easily and affordably created the space needed for your growing church with a new metal building system When looking for an answer to crowding troubles, the answer is certain to arrive. If smiling faces outnumber the seats in your church, then a metal church building is a great solution. The benefits of a pre-fabricated metal building include practicality and economical construction costs. Many customary churches find themselves in need of supplementary space for children's, youth or family activities. A metal church building is an excellent choice to solve your space problems. Building Permits/CodesDo I need a building permit to build my metal building? - You will almost always need a building permit. On occasion you will not need a permit to build but you should ALWAYS check with your local building inspector before purchasing a metal building. When I call my building inspector what should I tell them? - When you get in touch with your building inspector let him know what you're planning and you should be able to receive the information you'll need to get a building permit for your new metal building. What do I do if I need permit drawings? - We supply the permit drawings to you after you have committed to buy a metal building from us. We will not begin fabrication or shipment until you have completed the approval process. See the Approval Process section of our website. What about building codes and loads? - Every metal building that we ship is engineered to comply with regional building codes, wind load and snow load requirements (as stated on your plans). When you start designing your metal building, make sure to review your building code specifications very closely. Since there can be varying requirements within regions - you will need to confirm the codes by contacting your local building official. MetalBuildingDepot.Com is not responsible for confirming codes. Controlling CondensationTwo things must be present for condensation to occur: warm moist air and cool surface temperatures below the dew point. The proper control of these two factors can minimize condensation. In metal buildings, we are concerned with two different areas or locations: visible condensation which occurs on exposed surfaces below dew point temperatures, and concealed condensation which occurs when moisture has passed through the vapor retarder and into interior roof and/or wall cavities and then condenses on a surface below dew point temperature. Structural FramingAll frames are welded on a state-of-the-art computerized submerged welding system. We are capable of producing structural members up to 72" in depth, which gives us the ability to manufacture clear-span buildings up to 150 feet wide! A factory primer coating is applied to protect the beams during shipping and erection. All framing members shall be shop fabricated for field bolted assembly unless otherwise noted on plans and specifications. All building parts shall carry an identifying mark for easy field identification. Structural framing shall include tapered beam frames, tapered rigid frames, modular beam and columns, lean-to rafters and columns, canopy beams, intermediate columns bearing end frames and end wall columns. Steel used in the fabrication of built-up primary structural members shall have a minimum yield of 50 KSI. Hot rolled primary structural members shall have a minimum yield of 50 KSI. Cold rolled structural members shall have a minimum yield of 55 KSI. Primary framing shall be shop fabricated and include all holes required for attachment of secondary members and bracing. A continuous arc-welding process shall join flanges and webs of built-up welded members. End wall columns and rafters shall be "hot-rolled" built-up "I" or standard "cee" sections. Connections - All field connections shall be bolted. All primary bolted connections shall be furnished with high strength bolts conforming to A.S.T.M. A-325. All secondary bolted connections shall be furnished with machine bolts conforming to A.S.T.M.-A307. Thank you for visiting Metal Building for Simpson, North Carolina. We provide the best service and prices when shopping for metal buildings or steel buildings. |