Metal Building for Lindsay, Montana Build and Buy Online!
Condensation ControlThe condensation process occurs when warmer moist air comes in contact with cold surfaces such as framing members, windows and other thermally conductive accessories, or the colder region within the insulation itself (if moisture has penetrated the vapor retarder). Warm air, having the ability to contain more moisture than cold air, loses that ability when it comes in contact with cooler surfaces or regions. When this happens, excessive moisture in the air is released in the form of condensation. If this moisture collects in the insulation, the insulating value is decreased. In dealing with condensation, air may be considered to be a mixture of two gases-dry air and water vapor. One thousand cubic feet of air at 75°F can hold up to 1.4 pints of water. At 45°F, it can hold only 0.5 pints. Relative Humidity is a percentage measurement of the amount of water vapor present in the air in relation to the amount it is capable of holding at that temperature. Therefore, 50% Relative Humidity would mean that the air is carrying only one-half of the total amount of moisture that it could be holding at that particular temperature. Cold outside air is usually much drier than warm inside air. Therefore, you can lower the Relative Humidity by bringing in outside air to mix with and dilute the moist inside air. At 100% Relative Humidity, the air is "saturated." The temperature at which the air is saturated and can no longer hold additional moisture is called the dew point temperature. Whenever air temperature drops below its dew point, excess moisture will be released in the form of condensation. Condensation problems are most likely to occur in climates where temperatures frequently dip to 35°F or colder over an extended period of time. Roof Extensions and OverhangsExtensions can improve the appearance of a building but will cost more. Roof extensions add "curb-appeal" to some buildings, but will take more time to complete the erection of the building because of the amount of extra covering trim. Extensions can also help a building merge in better in an environment of conventionally constructed buildings in commercial areas. An overhang offers you some protection from the rain and shade from the sun. These options can be important when you receive many visitors to your building, by offering shelter from the elements. We offer two types of roof extensions: (1) Gable Extensions for endwalls (2) Eave Extensions for sidewalls. Using our system, you can easily and quickly design and price buildings with overhangs up to 5' on any or all of the walls. When in the Building Accessories section select Roof Extensions. INDUSTRIALAs a company rooted in American heavy industry, We understand and appreciate the importance of strength, dependability and economy in industrial structures. Our Dealers work closely with industrial building users to meet stringent construction schedules, assist with designs for machinery and inventory layouts, and assure the design and the manufacture of strong, stable, low-maintenance structures which enhance the image of their users. Our own in-house team of experienced engineers can also help design crane buildings with a unique combination of strengths and hook clearances to fit individual, industrial requirements and criteria. Clear spans of up to 150 feet wide and heights of up to 60 feet are available, while multi-span systems allow for unlimited widths. Our experienced engineers can provide flexibility in solving industrial needs through design and use of mezzanines, customized loading docks, and a variety of door systems. Whatever your company's requirements are for space, height, width, length or load capacity, a Metal Building system can be designed and manufactured to match them closely and economically. We are proud to serve you and to be an integral part of the American industrial machine. Proper Ventilation of a BuildingProper ventilation in a building can be an effective measure for condensation control. The end use of the building must be the controlling ventilation design parameter, especially above drop ceiling areas. Ventilation system design should be done at the initial building design stage. Use of a design professional is strongly recommended to assure the best possible system. CONDENSATION CAN BE MINIMIZED THROUGH CONSIDERATION OF CLIMATE, RELATIVE HUMIDITY AND THICKNESS OF INSULATION. Pre Engineered Steel BuildingsGrowth is good for every business. It can also be overwhelming when facilities, staff and production seem to be bursting at capacity. By adding needed space, it is possible to alleviate pressure by providing the appropriate workspace to achieve the greatest efficiency. Something that makes pre engineered steel buildings and steel storage buildings attractive to buyers is the flexibility of the external and internal floor plan. Every site has constraints that a conventional builder may be reluctant to work around, but metal buildings can be built to suit any site requirements. There should be no reason not to consider a pre-engineered steel building for your construction solution. Steel buildings provide comfort and amenities equal or greater than conventional construction methods. If you are renting office space, and considering building your own complex, you can instantly realize the benefits of owning a steel building. Thank you for visiting Metal Building for Lindsay, Montana. We provide the best service and prices when shopping for metal buildings or steel buildings. |